BPZQV - 0261100 8-HYDROXYQUINOLINE

Product Identification

Product ID:0261100 8-HYDROXYQUINOLINE
MSDS Date:05/01/1991
FSC:6810
NIIN:00-242-3642
MSDS Number: BPZQV

Responsible Party
FISHER SCIENTIFIC CO CHEMICAL DIV.
1 REAGENT LANE
FAIR LAWN, NJ 07410
US

Emergency Phone: 201-796-7100 OR 201-796-7523

Info Phone: 201-796-7100

Cage: 1B464

Contractor
FISHER SCIENTIFIC CO. CHEMICAL MFG DIV
FAIRLAWN, NJ 07410-2802 US

Telephone: 201-796-7100

Cage: 1B464

Ingredients

8-HYDROXYQUINOLINE (8-QUINOLINOL)

CAS: 148-24-3

RTECS: VC4200000

Fraction By Weight: 100%

Hazards

LD50 LC50 Mixture:ORAL LD50 (RAT) IS 1200 MG/KG
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:ACUTE: INHALATION/INGESTION/SKIN
ABSORPTION-ALL PRODUCE METHEMOGLOBIN IN BLOOD, CAUSING REDUCED
BLOOD FUNCTION. EYE CONTACT MAY CAUSE IRRITATION. CHRONIC:
PROLONGED OR REPEATED EXPOSURE MAY AFFECT LI VER, CENTRAL NERVOUS
SYSTEM, AND BONE MARROW; WEIGHT LOSS, ANEMIA, AND IRRITABILITY MAY
ALSO OCCUR.
Explanation of Carcinogenicity:8-HYDROQUINOLINE IS NOT LISTED BY IARC
AND NTP DUE A LACK OF SUFFICIENT EVIDENCE (CLASS 3 IARC) .
Effects of Overexposure:INGESTED/INHALED/SKIN CONTACT: HEADACHE,
CYANOSIS, SHALLOW BREATHING, DIZZINESS, CONFUSION, LETHARGY,
STUPOR, CONVULSIONS, COMA, JAUNDICE, PAIN IN URINATION, ANEMIA,
DEATH. EYE: REDNESS, TEARING, BLUR RED VISION.
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.

First Aid

First Aid:INHALED: MOVE TO FRESH AIR. GIVE ARTIFICIAL RESPIRATION IF
BREATHING STOPPED. GIVE OXYGEN IF BREATHING DIFFICULT. SEE DOCTOR.
EYES: FLUSH WITH LOTS OF WATER FOR 15 MINUTES OR UNTIL NO RESIDUE
REMAINS. SEE DOCTOR. SKIN: REMOVE CONTAMINATED CLOTHES. WASH WITH
SOAP AND WATER. INGESTED: IF CONSCIOUS, INDUCE VOMITING BY GIVING
SYRUP OF IPECAC, FOLLOWED BY WATER. TREAT SYMPTOMATICALLY AND
SUPPORTIVELY.

Fire Fighting

Flash Point:NON-FLAMMABLE
Extinguishing Media:DRY CHEMICAL OR CARBON DIOXIDE
Fire Fighting Procedures:WEAR SELF-CONTAINED BREATHING APPARATUS AND
PROTECTIVE GEAR. MOVE CONTAINER FROM FIRE IF POSSIBLE.
Unusual Fire/Explosion Hazard:SLIGHT FIRE HAZARD WHEN EXPOSED TO HEAT
OR FLAME.

Accidental Release

Spill Release Procedures:NO SPECIAL PRECAUTIONS INDICATED.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:NONE SPECIFIED BY MANUFACTURER.
Other Precautions:NONE SPECIFIED BY MANUFACTURER.

Exposure Controls

Respiratory Protection:IF ENGINEERING CONTROLS FAIL OR NON-ROUTINE
OPERATIONS OCCUR; USE NIOSH/MSHA APPROVED RESPIRATOR, SUPPLIED AIR
RESPIRATOR, OR SCBA, AS REQUIRED. USE IN ACCORDANCE WITH 29 CFR
1910.134.
Ventilation:PROVIDE LOCAL EXHAUST VENTILATION SYSTEM.
Protective Gloves:IMPERVIOUS
Eye Protection:SAFETY GLASSES/CHEMICAL SPLASH GOGGLES
Other Protective Equipment:IMPERVIOUS CLOTHING AS NEEDED TO PREVENT
PROLONGED OR REPEATED SKIN CONTACT.
Work Hygienic Practices:WASH HANDS AFTER USE AND BEFORE EATING,
DRINKING, OR SMOKING. LAUNDER CONTAMINATED CLOTHES BEFORE REUSE.
Supplemental Safety and Health
ANTIDOTE FOR METHOMOGLOBINEMIA (>25-40%): GIVE 1% METHYLENE BLUE
SOLUTION, 0.1 ML/KG INTRAVENEOUSLY OVER A 10 MINUTE PERIOD. IF NO
METHYLENE BLUE AVAILABLE; USE ASCORBIC ACID 1 GRAM SLOWLY
INTRAVENEOU SLY. ANTIDOTE WILL BE ADMINISTERED BY QUALIFIED MEDICAL
PERSONNEL ONLY.

Chemical Properties

HCC:T6
Boiling Pt:B.P. Text:512F,267C
Melt/Freeze Pt:M.P/F.P Text:167F,75C
Decomp Temp:Decomp Text:512F,267C
Spec Gravity:1.0 (WATER=1)
Solubility in Water:INSOLUBLE
Appearance and Odor:WHITE CRYSTALS OR CRYSTALLINE POWDER, DARKENS ON
EXPOSURE TO LIGHT

Stability

Stability Indicator/Materials to Avoid:YES
NONE KNOWN
Stability Condition to Avoid:NONE KNOWN
Hazardous Decomposition Products:NONE SPECIFIED BY MANUFACTURER.

Disposal

Waste Disposal Methods:DISPOSE OF IN ACCORDANCE WITH LOCAL, STATE AND
FEDERAL REGULATIONS.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.